PB DP FC 1x2xAWG22/7 SWB LSHF

PROFIBUS DP FC Steel Wire Braid Armoured LSHF Cable, 150 Ohm

Application

Armoured indoor and outdoor Installation cable:

– Halogen free and flame retardant

– Limited segment length (according to PROFIBUS – Net Manual)

– FastConnect-assembly

– UV resistant

– Silicon free

– Limited oil and grease resistance

Standards

  • EN 50170 part 8-2, cable type A, IEC 61158 and IEC 61784

Flame Rating

  • IEC 60332-1, IEC 60332-3-24
Construction
Conductor Stranded bare copper wire, ∅ 0.78 mm, (cross-section 0.37 mm²)
Insulation foam-skin-PE, Ø 2.55 mm
Stranding two cores green / red to the Pair
Bedding halogen free, flame retardant thermoplastic sheathing compound
Static screen PET-Al-Foil longitudinally applied
Braid tinned copper braid, coverage approx. 65%
Sheath halogen free, flame retardant thermoplastic sheathing compound acc. to
Armouring Galvanized Steel Wire Braid
Outer sheath halogen free, flame retardant thermoplastic sheathing compound
Outer Diameter Nom. 12.0 mm
Weight Nom. 208 kg/km
Tensile force N 450
Mechanical properties
Bending radius
Single bending ≥ 120 mm
Repeated bending ≥ 240 mm
Temperature range – 10°C to + 75°C
Transport and storage – 10°C to + 75°C
Installation – 5°C to + 50°C
Electrical properties at 20°C
Loop resistance ≤ 110 Ω
Characteristic impedance (Nominal) 150 Ω ± 20Ω
Mutual capacitance (at 1 kHz) approx. 28.5 nF/km
Capacitance unbalance to earth max. 1.5 nF/km
Test Voltage (DC, 1 min) Core/Core and Core/Screen 1 kV
Electrical Data at 20°C
Frequency (kHz) Impedance (Ohm) Attenuation (dB/100m)
9.6 kHz 270 ± 27 ≤ 0.3
38.4 kHz 185 ± 18.5 ≤ 0.4
1 MHz
3 MHz 150 ± 15
4 MHz 150 ± 15 ≤ 2.5
16 MHz 150 ± 15 ≤ 4.9
20 MHz 150 ± 15
Ordering Information
P/N Product Description P.U
TBC PROFIBUS DP FC Steel Wire Braid Armoured LSHF Cable, PB DP FC 1x2xAWG22/7 SWB LSHF 1000m/drum

PB DP FC 1x2xAWG22/1 LSHF-FR

PROFIBUS FC LSHF-FR Cable, 150 Ohm

Construction
Conductor Solid Bare Copper Wire, ∅ 0.64 mm, (cross-section 0.32 mm²)
Insulation foam-skin-PE, ∅ 2.5 mm
Stranding two cores green / red to the Pair
Bedding halogen free, flame retardant thermoplastic sheathing compound
Static screen PET-Al-Foil longitudinally applied
Braid tinned copper braid, coverage approx. 60%
Sheath halogen free, flame retardant thermoplastic sheathing compound
Outer Diameter Nom. 8.0 mm
Weight Nom. 83 kg/km
Tensile force N 800
Mechanical properties
Bending radius
Single bending ≥ 60 mm
Repeated bending ≥  80 mm
Temperature range – 15°C to + 70°C
Transport and storage – 15°C to + 70°C
Installation – 15°C to + 50°C
Electrical properties at 20°C
Loop resistance ≤110 Ω/km
Screen resistance nominal ≤ 9.5 Ω/km
Characteristic impedance (Nominal) 150 Ω
Mutual capacitance (at 1 kHz) ca. 28.5 nF/km
Test Voltage (DC, 1 min) Core/Core and Core/Screen 1 kV
Operating voltage (RMS) ≤ 100 V

Application

Installation cable:

– Halogen free and flame retardant

– Limited segment length (according to PROFIBUS – Net Manual)

– Fast Connect-assembly

– UV resistant

– Silicon free

– Limited oil and grease resistance

Flame Rating

  • IEC 60332 – 1, IEC 60332-3-24
Electrical Data at 20°C
Frequency (kHz) Impedance (Ohm) Attenuation (dB/100m)
9.6 kHz 270 ± 27 ≤ 0.25
38.4 kHz 185 ± 18.5 ≤  0.4
1 MHz
3 MHz 150 ± 15
4 MHz 150 ± 15 ≤  2.2
16 MHz 150 ± 15 ≤  4.2
20 MHz 150 ± 15
Ordering Information
P/N Product Description P.U
60011470 PROFIBUS FC LSHF-FR Cable, ICSPB DP FC 1x2xAWG22/1 LSHF-FR 1000m/drum

PB DP BASIC 1x2xAWG22/1 LSHF

PROFIBUS DP Basic LSZH Cable,150 Ohm

Application

Installation cable:

– Halogen free and flame retardant

– Limited segment length (according to PROFIBUS – Net Manual)

– UV resistant

Standards

  • IEC 61158-2

Fire Rating

  • IEC 60332 -3-24
Construction
Conductor Solid Bare Copper Wire, 22AWG
Insulation Foam-skin-PE
Stranding two cores green / red to the pair and two fillers
Static screen PET-Al-Foil longitudinally applied
Braid Tinned Copper Braid
Sheath Low Smoke Zero Halogen compound
Violet RAL 4001
Outer Diameter Nom. 7.8 mm
Weight Nom. 71 kg/km
Mechanical properties
Bending radius ≥ 60mm
Max. operating voltage – 40°C to + 80°C
Electrical properties at 20°C
Conductor resistance ≤ 55Ω/km
Characteristic impedance (Nominal) 150 Ω
Mutual capacitance (at 1 kHz) ca. 28.5 nF/km
Test Voltage (DC, 1 min) Core/Core and Core/Screen 1 kV
Operating voltage (RMS) 300 V
Ordering Information
P/N Product Description P.U
PDP122FLVVL-5H PROFIBUS DP Data Communication Cable Cable, BC/FPE/OS/TCB/LSZH UV 1PR x 22AWG VIOLET 500m/drum

FF FC 1x2xAWG18/7 SWB LSZH

FOUNDATION Fieldbus FC FLEX Steel Wire Braid Armoured LSZH Cable

Construction
Conductor stranded bare copper wires, 7×0.40, ø 1.2 mm, (cross-section AWG18/7)
Insulation foam-skin-PE, ø 2.55 mm
Stranding two cores blue / orange to the pair
Bedding LSHF, filling the interstices.
Static screen PET-Al-Foil longitudinally applied.
Braid tinned copper braid, coverage approx. 70%
Sheath LSZH, ø 8.0 mm
Colour Grey
Armouring galvanized steel wire braid, optical coverage 85%, ø 9.3 mm
Outer sheath LSZH, ø12.0 mm
Colour Grey
Outer Diameter Nom. 12.0 mm
Weight Nom. 202 kg/km
Tensile force N 500
Mechanical properties
Bending radius
Single bending ≥ 60 mm
Repeated bending ≥ 120 mm
Temperature range – 30°C to + 70°C
Transport and storage – 30°C to + 70°C
Installation – 5°C to + 50°C
Electrical properties at 20°C
Loop resistance ≤ 43.6 Ω/km
Screen resistance nominal 12 Ω/km
Characteristic impedance (at 31.25 kHz) 100Ω ± 20 Ω
Mutual capacitance (at 1 kHz) approx. 60 nF/km
Capacitance unbalance to earth max. 2 nF/km
Test Voltage (DC, 1 min) Core/Core and Core/Screen 1 kV
Operating voltage (RMS) ≤ 100 V
Inductance (nominal) 0.70 mH/km

Application

Spur and trunk cable for flexible installation indoor and outdoor on racks in conduits,

– Fast connect Assembly

– Halogen free and flame resistant

– Silicon free

– Oil and grease resistance

Standards

  • IEC 61158 and IEC 61784
  • Cable Type A acc. to FOUNDATION Fieldbus

Fire Rating

  • IEC 60332-1, IEC 61034 – 2, IEC 60754 – 1 / 2
Electrical Data at 20°C
Frequency (kHz) Impedance (Ohm) Attenuation (dB/100m) Propagation delay change (µs/km)
7.9-39 ≤ 1.7
31.25 100 ± 20
39 ≤ 0.3
Ordering Information
P/N Product Description P.U
1030290 FOUNDATION Fieldbus FC FLEX Steel Wire Braid Armoured LSZH Cable,FF FC 1x2xAWG18/7 SWB LSZH 1000m/drum

FF FC 1x2xAWG18/7 LSHF-FR

FOUNDATION Fieldbus FC FLEX LSZH-FR Cable

Application

Spur and trunk cable for flexible installation indoor and outdoor on racks in conduits, Fast connect Assembly

– UV resistant

– Silicon free

– Oil and grease resistant

Standards

  • IEC 61158 and IEC 61784
  • Cable Type A acc. to FOUNDATION Fieldbus

Fire Rating

IEC 60332-1, IEC 60332-3-24, IEC 60754-1/2

Construction
Conductor Stranded bare copper wires, 7×0.40, ∅ 1.2 mm, (cross-section AWG18/7)
Insulation foam-skin-PE, ∅ 2.55 mm
Stranding two cores green / red to the Pair
Bedding halogen free, flame-retardant thermoplastic sheathing compound
acc. to EN 50290-2-27, filling the interstices.
Static screen PET-Al-Foil longitudinally applied.
Braid tinned copper braid, coverage approx. 70%
Sheath halogen free, flame-retardant thermoplastic sheathing compound
acc. to EN 50290-2-27, 0 8.0 mm
Colour yellow
Outer Diameter Nom. 8.0 mm
Weight Nom. 83 kg/km
Tensile force N 180
Mechanical properties
Bending radius
Single bending ≥ 40 mm
Repeated bending ≥ 80 mm
Temperature range – 40°C to + 70°C
Transport and storage – 40°C to + 70°C
Installation – 5°C to + 50°C
Electrical properties at 20°C
Loop resistance ≤ 43.6 Ω/km
Screen resistance nominal 12 Ω/km
Characteristic impedance (at 31.25 kHz) 100 Ω ± 20 Ω
Mutual capacitance (at 1 kHz) approx. 60 nF/km
Capacitance unbalance to earth max. 2 nF/km
Insulation resistance ≥ 5 GΩkm
Test Voltage (DC, 1 min) Core/Core and Core/Screen 1 kV
Operating voltage (RMS) ≤ 100 V
Inductance (nominal) 0.70 mH/km
Electrical Data at 20°C
Frequency (kHz) Impedance (Ohm) Attenuation (dB/100m) Propagation delay change (µs/km)
7.9-39 ≤ 1.7
31.25 100 ± 20
39 ≤ 0.3
Ordering Information
P/N Product Description P.U
1025038 FOUNDATION Fieldbus FC FLEX LSHF-FR Cable, FF FC 1x2xAWG18/7 LSZH-FR 1000m/drum

Li-2YC11Y 2 x 2 x 0.22 mm² FRNC

CanBus-Cable

Application

  • The following CanBus cable is suitable for transmission of CanBus signals according to DIN19245 and EN 50170
  • The following CanBus cable is suitable for transmission of CanBus signals according to ISO 11898 – 2
  • The cable is suited for fixed indoor and outdoor installation and under certain conditions also for mobile use.
  • The cable is halogen free,flame retardant and oil resistant. The sheath material is tested in Hydraulic oil.
  • ARAL VITAM 32, Mobil DTE 13 M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320

Flame resistance

  • IEC 60332 – 1,IEC -60332-3,IEC 60754 – 1 /2
Construction
Conductor Stranded bare copper wire, diameter 7 x 0.20 mm            
ø 0.60 mm(cross section 0.22 mm²)
Insulation PE,
ø1.75± 0.05 mm
Wall Thickness 0.46mm
Colour code Pair 1: 1 x white, 1 x brown
Core identification Pair 2: 1 x yellow, 1 x green
Cable lay up 4 cores twisted to a star quad
ø 4.2 mm
Wrapping 1 x PET-foil, overlapping
ø 4.3 mm
Overall screen Tinned copper braid
ø 5.0 mm, Optical coverage ≥ 85%
Foil 1 x PET-foil under sheath
ø 5.1 mm
Sheath PUR Low Smoke Zero Halogen
ø 6.9 ± 0.2 mm
Sheath colour Black, RAL 9005
Outer Diameter Nom. 6.9 mm
Weight Nom. 70 kg/km
Tensile force N 165
Mechanical properties
Bending radius
– moving application- fixed application
≥ 10 x outer diameter of cable

≥ 5 x outer diameter of cable

Operating temperature – 40°C up to + 85°C
UV resistance acc. to IEC60068-2-5
Ozone resistance acc. to EN 60811-2-1, clause 8
Smoke density acc. to EN 50268-2, IEC61034-1 and 2
Corrosivity EN 50267-1 and 2, IEC 60754-1 and 2
Electrical properties at 20°C
Conductor resistance (at 20 ± 5 °C) ≥ 87 /km
Characteristic impedance at 1 MHz 120 Ω± 15%
Capacitance at 800 Hz (nominal) 41 nF/kmm
Insulation resistance (at 20 ± 5 °C and 500 V) ≥10 GΩxkm
Capacitance unbalance (pair to ground) 1.2 kV
Ordering Information
P/N Product Description P.U
1003018 CS2878600 CanBus, Li-2YC11Y 2 x 2 x 0.22 mm² FRNC 1000m/drum

Li-09YS(St)C11Y 2 x 0.35 mm² LSZH

CanBus-Cable

Construction
Conductor Stranded bare copper wire, diameter 7 x 0.26 mm                     
ø 0.78 mm
(cross section 0.35 mm²)
Insulation Foam-Skin PP,
ø 2.2 ± 0.1 mm
wall thickness 0.71 mm
Twisting 2 cores + 2 x PP-fillers twisted to the pair
ø 4.4 mm
Core identification 1x white, 1x green
Overall screen 1 x PET-Al-foil +
ø 4.6 mm
tinned stranded drain wires 19 x 0,15 mm
+ tinned copper braid
ø 5.2 mm
optical coverage ≥ 65%
Foil 1 x PET-foil under sheath
ø 5.3 mm
Sheath PUR Low Smoke Zero Halogen
ø 6.8 ± 0.2 mm
wall thickness 0.75 mm
Sheath colour Black, RAL 9005
Outer Diameter Nom. 6.8 mm
Weight Nom. 46.7 kg/km
Tensile force N 165
Mechanical properties
Bending radius during installation
– without load
– with load
> 5 x cable diameter;

> 10 x cable diameter

Operating temperature – 30°C up to + 70°C
Storage temperature -40°C up to 85°C
UV resistance of sheath material acc. to IEC60068-2-5
Ozone resistance acc. to EN 60811-2-1, clause 8
Smoke density acc. to EN 50268-2, IEC61034-1 and 2
Corrosivity acc. EN 50267-1 and 2, IEC 60754-1 and 2
Electrical properties at 20°C
Conductor resistance (at 20 ± 5 °C) ≥ 54.5Ω /km
Characteristic impedance at 1 MHz 120 Ω± 15%
Insulation resistance (at 20 ± 5 °C and 500 V) >10 GΩxkm
Operating voltage (50 Hz, rms) 60 V
Test voltage (AC, 1 min) Core/core and core/screen 1.2 kV

Application

  • The following CanBus cable is suitable for transmission of CanBus signals according to DIN19245 and EN 50170
  • The following CanBus cable is suitable for transmission of CanBus signals according to ISO 11898 – 2
  • The cable is suited for fixed indoor and outdoor installation and under certain conditions also for mobile use.
  • The cable is halogen free,flame retardant and oil resistant. The sheath material is tested in Hydraulic oil.
  • ARAL VITAM 32, Mobil DTE 13M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320

Flame resistance

  • IEC 60332 – 1,IEC -61034-2,IEC 60754 – 1 /2

Ordering Information
P/N Product Description P.U
1003011 CS2875900 CanBus-Cable, Li-09YS(St)C11Y 2 x 0.35 mm² LSZH 1000m/drum

EIB/KNX – BUS, LSZH

EIB/KNX-Bus Cable

Symmetrical data cable for EIB/KNX-BUS Systems

Application

EIB (European Installation Bus) cable is a special type of BUS cable suitable for use in KNX systems.
EIB/KNX is a shielded bus cable which meets the requirement of “European Installation Bus” standard. It’s widely use in KNX communication for building management for lighting control, heating, air-conditioning, time management, etc.
The cable can be used in dry, wet and damp areas either inside or outside (if protected from direct sunlight)

Fire Rating

  • IEC 60332-1
Construction
Conductor Copper wire, bare 0.5 mm2, ø 0.80 mm
Insulation PE, 1.6 mm ø
Core identification Pair 1: Red, Black, Pair 2: Yellow, White
Pair stranding 2 conductors to the pair
Cable lay up 1 or 2 pairs to the core
Wrapping 1 x PET foil
Overall shielding Laminated AL-foil + Tinned copper drain wire
Outer Sheath LSZH, Green RAL 6018
Mechanical properties
Operating temperature – 25°C up to + 70°C
Min. Installation temperature – 5°C up to + 60°C
Minimum bending radius (without load)  4 x D
Smoke density (only for LSFROH types) acc. to IEC 61034-2
Corrosivity of fire gases (only for LSZH types) acc. to IEC 60754-1/2
Electrical properties at 20°C
Max. Cond. Resistance DC (max.) 37.5 Ω/km
Ordering Information
P/N Product Description P.U
EIB2P0.8L-GN EIB BUS Cable, 2PR x 0.8mm BC Shielded LSZH Green 500m/drum