Category: product
Video Cables
AC10 SS 23/1 nxP
Audio Cable
Application
- Audio cables are used in professional broadcasting systems for the transmission of analog and digital audio signals.
Standards
- Basing upon ARD-Specification and acc.
to AES/EBU-Recommendation.)
Fire Rating
- VDE 0472 part 804 class B or C and IEC 60332-1 or 60332-3 cat. CF
Construction | |
---|---|
Conductor | AWG23/1, solid copper wire, bare 0.56 mm (cross section 0.26 mm²) |
Insulation | Foam-skin-PE |
Pair stranding | Two cores twisted to the pair |
Pair identification | a – core: white, b – core: blue (the above colours in regular intervals) |
Pair screen | 2.9 mm Al-PET-foil, Aluminium outside + solid copper drain wire, tinned |
Pair insulation of the one pair cable | PET-foil |
Overall screen of the one pair cable | Tinned Copper Braid |
Pair sheath of the multi-pair cables | LSZH |
Colour and identification | grey RAL 7001 with number printing |
Sheath | LSZH |
Sheath colour | grey, RAL 7001 |
Outer Diameter | Nom. 4.6(1pair) – 15.6(12pair) mm |
Weight | Nom. 27(1pair) – 320 (12pair) kg/km |
Tensile force N | Nom. 80(1pair) – 725(12pair) |
Mechanical Properties | ||
---|---|---|
Bending radius during installation | with load | 15 x cable diameter |
without load | 10 x cable diameter | |
Temperature range | – 30 °C to + 70 °C |
Electrical Properties | ||
---|---|---|
BendaDC loop resistance | 165 Ω/km | |
Insulation resistance | ≥ 2000 MΩxkm | |
Mutual capacitance at 800 Hz | nom. 45 nF/km | |
Capacitance unbalance (pair to ground) | ≥1200 pF/km | |
Velocity ratio | approx. 78 % | |
Test voltage (50 Hz, 1 min) | 700 V rms | |
Characteristic impedance | 6 MHz : 110 Ω ± 10% |
Ordering Information | ||||
---|---|---|---|---|
P/N | Product Description | P.U | ||
1002105 CT7649010 | 1x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002115 CT7649710 | 2x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002106 CT7649110 | 3x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002108 CT7649210 | 5x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002109 CT7649310 | 6x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002103 CT7648710 | 8x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002111 CT7649410 | 10x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum | ||
1002113 CT7649510 | 12x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxP | 1000m/drum |
HD PRO 0.6/2.8 AF
HD Video Cable 75Ω
Construction | |
---|---|
Inner conductor | Solid copper wire, bare, diameter 1.0 mm |
Insulation | Foam-PE |
Outer conductor | Al-PET-Al-foil under tinned copper braid |
Sheath | LSZH, PVC, PUR diameter 7.0 mm green, RAL 6018, blue, RAL 5015 |
Weight | Nom. 28 kg/km |
Tensile force N | 60 |
Electrical Properties at 20°C | ||
---|---|---|
DC resistance | Inner conductor | 22 Ω/km |
Outer conductor | 7 Ω/km | |
Mutual capacitance | – | 56 pF/m |
Characteristic impedance | – | 75 Ω± 0.75 Ω |
Velocity ratio | – | 78 % |
Application
- Video cables are primary used in closed
circuit TV systems and in several studio
applications for transmission of image
signals.
Standards
- For analogue and digital video signals
(Composite, component, SDI, SDV, SDTI, HDTV)
Fire Rating
- IEC 60332-1/2, IEC 60332-3, IEC 60754-2
Electrical Data | ||||
---|---|---|---|---|
Attenuation (dB/100m) | Return loss (dB) | |||
Frequency (MHz) | Frequency (MHz) | |||
1 | 1.2 | 50 – 300 |
≤ 26 |
|
3 | 1.9 | 300 – 3000 |
≤ 22 |
|
5 | 2.5 | 3000 – 3500 |
≤ 18 |
|
10 | 3.5 | 3500 – 5000 |
≤ 15 |
|
30 | 5.9 | – | – | |
100 | 10.0 | – | – | |
200 | 14.1 | – | – | |
300 | 17.8 | – | – | |
500 | 24.0 | – | – | |
800 | 29.7 | – | – | |
1000 | 33.2 | – | – | |
1500 | 39.6 | – | – | |
2250 | 50.2 | – | – | |
3000 | 60.9 | – | – | |
3500 | 65.8 | – | – | |
4000 | 69.8 | – | – | |
4500 | 74.2 | – | – | |
5000 | 78.9 | – | – |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
1014488 | HD PRO 0.6/2.8 AF, HD Video Cable 75Ω , HD PRO 0.6/2.8 AF | 1000m/drum |
ICS IE ToughCat 7S* Armoured
S/FTP Installation Cable for tougher environments
Construction | |
---|---|
Conductor | Solid copper wire, ø 0.56 mm (AWG 23) |
Insulation | foamskin PE |
Twisting | 2 cores to the pair |
Pair screen | Al-laminated plastic foil |
Cable lay up | 4 pairs (PiMF) to the core |
Screen | Tinned Copper Braid |
Inner Sheath | Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1) |
Outer sheath | Grey RAL7035 |
Armouring | Galvanized steel wire braid, Wire diameter 0,25mm |
Outer sheath | Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1) |
Outer Diameter | Nom. 10.6 mm |
Weight | Nom. 168 kg/km |
Mechanical properties | ||
---|---|---|
Bending radius | Installation | 8 x D |
Installed | 4 x D | |
Temperature range | During operation | -40°C to + 85°C |
During installation | -15°C to + 50°C | |
Fire load | 4 pair | 1540 MJ/km |
Maximum tensile load | During operation | No load |
During installation | 200 N |
Electrical properties at 20°C ± 5°C | ||
---|---|---|
Loop resistance | – | ≤ 150 Ω/km |
Resistance unbalance | – | ≤ 2% |
Mutual Capacitance | at 800 Hz | Nom. 43 nF/km |
Capacitance unbalance | (pair/ground) | ≤ 1500 pF/km |
Characteristic impedance | (1-100 MHz) | 100 Ω± 5 Ω |
(100 – 250) MHz | 100 Ω± 10 Ω | |
(250 – 600) MHz | 100 Ω± 15 Ω | |
Nominal velocity of propagation | – | ca. 79 % |
Application
- Generic Data transmission. This cable is a Cat7 S/FTP cable is meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. The Steel Wire Braid offers extra robustness rodent protection.
Standards
- EN50173-1, EN50288-4-1
- ISO/IEC 11801, IEC61156-5
- Det Norske Veritas(DNV) specification No. 6-827.50-2
Flame Rating
- IEC 60332 – 1 & IEC 60332-3-24
Chemical Resistance
- Mineral oils IRM902(IEC 60811-2-1)
- Diesel – IRM 903(IEC60811-2-1)
Certification
- This cable is based on the unarmoured version certified by: Det Norske Veritas(DNV)
Electrical Transmission Characteristics at 20°C | ||||||||
---|---|---|---|---|---|---|---|---|
F | Attenuation | NEXT | PS-NEXT | ACR | PS-ACR | ELFEXT | PS-ELFEXT | Return loss |
(MHZ) | (dB/100m) | (dB) | (dB) | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) |
1 | 1.8 | 100 | 97 | 98 | 95 | 105 | 105 | – |
4 | 3.4 | 100 | 97 | 97 | 94 | 105 | 102 | 27 |
10 | 5.4 | 100 | 97 | 95 | 92 | 97 | 94 | 30 |
16 | 6.8 | 100 | 97 | 93 | 90 | 93 | 90 | 30 |
20 | 7.7 | 100 | 97 | 92 | 89 | 91 | 88 | 30 |
31.25 | 9.6 | 100 | 97 | 92 | 89 | 91 | 88 | 30 |
62.50 | 13.7 | 100 | 97 | 86 | 83 | 81 | 78 | 30 |
100 | 17.4 | 100 | 97 | 83 | 80 | 77 | 74 | 30 |
125 | 19.5 | 95 | 92 | 75 | 72 | 75 | 72 | 26 |
155.5 | 21.9 | 94 | 91 | 72 | 69 | 73 | 70 | 26 |
175 | 23.3 | 93 | 90 | 70 | 67 | 72 | 69 | 25 |
200 | 25.0 | 92 | 89 | 67 | 64 | 71 | 68 | 25 |
250 | 28.1 | 90 | 87 | 62 | 59 | 69 | 66 | 24 |
300 | 30.9 | 89 | 86 | 58 | 55 | 67 | 64 | 24 |
600 | 44.8 | 85 | 82 | 40 | 37 | 61 | 58 | 22 |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
60027371 | ToughCat7S_SWB SFTP 4×2/0.56 500DP | 500m/drum |
ICS IE ToughCat 7 LSHF-FR MUD
S/FTP Installation Cable 4x2xAWG23/7 for tougher environments

Application
- Generic Data transmission. This Cat7 S/FTP cable is based on our DNV and Llyod Register certified ToughCat,but with an additional flame retardant, halogen-free, low smoke MUD protecting outer jacket. This cable is meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units
Standards
- EN50173-1, EN50288-4-1
- ISO/IEC 11801, IEC61156-5
- Det Norske Veritas(DNV) specification No. 6-827.50-2
Flame Rating
- MUD protecting outer sheath: IEC60754-1, IEC 61034, IEC 60332-3-24
- Inner Sheath: IEC60754-1, IEC 61034, IEC 60332-3-24
Chemical Resistance
- Mineral oils IRM902(IEC 60811-2-1)
- Diesel – IRM 903(IEC60811-2-1)
Construction | |
---|---|
Conductor | Stranded copper wire, cross section ∅ 0.27 mm² (AWG23/7) |
Insulation | PE |
Twisting | 2 cores to the pair |
Cable lay up | 4 pairs |
Pair screen | Al-laminated plastic foil around each pair |
Overall screen | Tinned Copper Braid |
Inner Sheath | Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1) |
Colour | Grey RAL 7035 |
Outer sheath | MUD protecting |
Colour | Grey RAL 7024 |
Outer Diameter | Nom. 10.1 mm |
Weight | Nom. 112 kg/km |
Tensile force N | 100 |
Mechanical properties | ||
---|---|---|
Bending radius | Without load | 8 X D |
With load | 4 x D | |
Temperature range | During operation | -40°C to + 85°C |
During installation | -15°C to + 50°C | |
Maximum tensile load | During operation | No load |
During installation | 100 N |
Electrical properties at 20°C± 5°C | ||
---|---|---|
DC Loop resistance | – | ≤ 138 Ω/km |
Resistance unbalance | – | ≤ 2% |
Mean Characteristic impedance | @ 100 MHz | 100 Ω± 5 Ω |
Nominal velocity of propagation | – | 76% |
Electrical Transmission Characteristics at 20°C | |||||
---|---|---|---|---|---|
Freq. | Attenuation | NEXT | ACR | Return loss | PS-NEXT |
(MHZ) | (dB/100m) | (dB) | (dB/100m) | (dB) | (dB) |
1 | 2.0 | 90 | 88 | – | 87 |
4 | 3.6 | 90 | 86 | 27 | 87 |
10 | 5.5 | 90 | 84 | 30 | 87 |
16 | 7.5 | 90 | 82 | 30 | 87 |
20 | 7.7 | 90 | 82 | 30 | 87 |
31.25 | 9.8 | 90 | 80 | 30 | 87 |
62.50 | 14.0 | 86 | 72 | 30 | 83 |
100 | 17.9 | 83 | 65 | 30 | 80 |
155 | 22.4 | 81 | 59 | 26 | 78 |
200 | 25.6 | 78 | 52 | 25 | 75 |
250 | 28.8 | 77 | 48 | 25 | 75 |
300 | 31.6 | 73 | 41 | 23 | 70 |
600 | 45.7 | 71 | 25 | 20 | 68 |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
60015695 | ToughCat MUD C7 S/FTP 4Px0.27mm² | 500m/drum |
ICS IE ToughCat 7 LSHF-FR
S/FTP Installation Cable 4x2xAWG23/7 for tougher environments
Construction | |
---|---|
Conductor | Stranded copper wire, cross section 0.27 mm² (AWG23/7) |
Insulation | PE |
Twisting | 2 cores to the pair |
Cable lay up | 4 pairs |
Pair screen | Al-laminated plastic foil around each pair |
Overall screen | Tinned Copper Braid |
Sheath | Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1), diameter 8.1 mm |
Colour | Grey RAL 7035 |
Outer Diameter | Nom. 8.1 mm |
Weight | Nom. 75 kg/km |
Tensile force N | 100 |
Mechanical properties | ||
---|---|---|
Bending radius | Without load | 8 x D |
With load | 4 x D | |
Temperature range | During operation | -40°C to + 85°C |
During installation | -15°C to + 50°C | |
Fire load | 4 pair | 670 MJ/km |
Maximum tensile load | During operation | No load |
During installation | 140 N |
Electrical properties at 20°C | ||
---|---|---|
DC Loop resistance | – | ≤ 138 Ω/km |
Resistance unbalance | – | ≤ 2% |
Mean Characteristic impedance | @ 100 MHz | 100 Ω± 5 Ω |
Nominal velocity of propagation | – | 76% |
Application
- Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units.
Standards
- EN50173-1,EN50288-4-1
- ISO/IEC 11801,IEC61156-5
- Det Norske Veritas(DNV) specification No. 6-827.50-2
Flame Rating
- IEC 60332 – 1 , IEC 60332-3-24, IEC -61034-2, IEC 60754 – 1 /2
Chemical Resistance
- Mineral oils IRM902(IEC 60811-2-1)
- Diesel – IRM 903(IEC60811-2-1)
Certification
- This cable is certified by :Det Norske Veritas(DNV) and American Bureau of Shipping(ABS)
Electrical Transmission Characteristics at 20°C | |||||
---|---|---|---|---|---|
Freq. | Attenuation | NEXT | ACR | Return loss | PS-NEXT |
(MHZ) | (dB/100m) | (dB) | (dB/100m) | (dB) | (dB) |
1 | 2.0 | 90 | 88 | – | 87 |
4 | 3.6 | 90 | 86 | 27 | 87 |
10 | 5.5 | 90 | 84 | 30 | 87 |
16 | 7.5 | 90 | 82 | 30 | 87 |
20 | 7.7 | 90 | 82 | 30 | 87 |
31.25 | 9.8 | 90 | 80 | 30 | 87 |
62.50 | 14.0 | 86 | 72 | 30 | 83 |
100 | 17.9 | 83 | 65 | 30 | 80 |
155 | 22.4 | 81 | 59 | 26 | 78 |
200 | 25.6 | 78 | 52 | 25 | 75 |
250 | 28.8 | 77 | 48 | 25 | 74 |
300 | 31.6 | 73 | 41 | 23 | 70 |
600 | 45.7 | 71 | 25 | 20 | 68 |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
60015820 | ToughCat C7 LSHF-FR 4×2/0.27mm2 | 500m/drum | |
60030363 | ToughCat C7 LSHF-FR 4×2/0.27mm2 | 1000m/drum |
ICS IE ToughCat 5e LSHF-FR
S/FTP Installation Cable 4x2xAWG24/7 for tougher environments
Construction | |
---|---|
Conductor | Stranded copper wire, cross section 0.22 mm² (AWG24/7) |
Insulation | PE |
Twisting | 2 cores to the pair |
Cable lay up | 4 pairs |
Pair screen | Al-laminated plastic foil around each pair |
Overall screen | Copper braid, tinned |
Sheath | Oil resistant, Flame retardant and halogen free LSZH-FR (SHF1) |
Colour | Grey RAL 7035 |
Outer Diameter | Nom. 7.7 mm |
Weight | Nom. 68 kg/km |
Tensile force N | 100 |
Mechanical properties | ||
---|---|---|
Bending radius | Without load | 8 x D |
With load | 4 x D | |
Temperature range | During operation | -40°C to + 85°C |
During installation | -15°C to + 50°C | |
Fire load | 4 pair | 670 MJ/km |
Maximum tensile load | During operation | No load |
During installation | 100 N |
Electrical properties at 20°C | ||
---|---|---|
DC Loop resistance | – | ≤ 158 Ω/km |
Resistance unbalance | – | ≤ 2% |
Insulation resistance | (500 V) | ≥ 5000 MΩxkm |
Capacitance | at 800 Hz | Nom. 43 nF/km |
Mean Characteristic impedance | @ 100 MHz | 100 Ω± 5 Ω |
Nominal velocity of propagation | – | 75% |
Application
- Generic Data transmission. This cable is a Cat5e S/FTP cable is meant for use as installation/horizontal cable in tougher electrical and mechanical environment,including ships and offshore units.
Standards
- EN 50288-2-1
- Det Norske Veritas(DNV GL) Class Program DNVGL-CP-0403 and Lloyd Register approval system 2002
Flame Rating
- IEC 60332 – 1, IEC 60332-3-24
Chemical Resistance
- Mineral oils IRM902(IEC 60811-2-1)
- Diesel – IRM 903(IEC60811-2-1)
Certification
- This cable is certified by :Det Norske Veritas(DNV) and Llyod Register
Electrical Data Nominal at 20°C | ||||||||
---|---|---|---|---|---|---|---|---|
Freq. | Attenuation | NEXT | ACR | Return loss | PS-NEXT | PS-ACR | ELFEXT | PS-ELFEXT |
(MHZ) | (dB/100m) | (dB) | (dB/100m) | (dB) | (dB) | (dB/100m) | (dB/100m) | (dB/100m) |
1 | 2.1 | 90 | 88 | – | 87 | 85 | 85 | 82 |
4 | 4.0 | 90 | 86 | 27 | 87 | 83 | 85 | 82 |
10 | 6.3 | 90 | 84 | 30 | 87 | 81 | 79 | 76 |
16 | 8.0 | 90 | 82 | 30 | 87 | 79 | 75 | 72 |
20 | 9.0 | 90 | 81 | 30 | 87 | 78 | 73 | 70 |
31.25 | 11.4 | 90 | 79 | 30 | 87 | 76 | 69 | 66 |
62.50 | 16.50 | 86 | 70 | 30 | 83 | 67 | 63 | 60 |
100 | 21.3 | 83 | 62 | 30 | 80 | 59 | 59 | 56 |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
60015830 | ToughCat C5e LSHF-FR 4×2/0.22mm² 500DP | 500m/drum | |
60015833 | ToughCat C5e LSHF-FR 4×2/0.22mm² 1000DP | 1000m/drum |
Draka UC400 Cat.6 U/FTP 23AWG LSFRZH AR_AT_UV
Category cable for demanding environments

Application
- Generic Data transmission. This cable is a Cat6 U/FTP cable is meant for use as installation/horizontal cable in demanding electrical and mechanical environment.
Standards
- ANSI/TIA 568.2-D;
- ISO/IEC 11801-1/2; IEC 61156 – 5
- EN 50173; EN 50288-5-1
Flame Rating
- IEC 60332-1, IEC 60332-3-24
Construction | |
---|---|
Conductor | Solid copper wire, (AWG23) |
Insulation | Foam PE |
Twisting | 2 cores to the pair |
Pair Screen | Individual Aluminium Foil Polyester Tape with drain wire |
Outer Sheath | LSFRZH. AR-AT-UV |
Sheath Colour | Black |
Mechanical properties | ||
---|---|---|
Bending radius | Installation | 8 X D |
Temperature range | During operation | -20°C to + 70°C |
During installation | 0°C to + 50°C | |
Maximum Pulling Force | During installation | 100N |
Electrical properties at 20°C | ||
---|---|---|
DC Loop resistance | ≤ 187.6 Ω/km | |
DC Resistance unbalance | ≤ 5% | |
Mutual capacitance | at 1kHz | ≤ 5.6nF/100m |
Capacitance unbalance | (pair/ground) | ≤ 536 ns/100m |
Velocity of Propagation | Nom. 69% |
Electrical Data at 20°C | |||||
---|---|---|---|---|---|
Freq. | Max. Attenuation | Min.NEXT | Min.PS-NEXT | Min.Return Loss | |
(MHZ) | (dB/100m) | (dB) | (dB) | (dB) | |
1 | 2.0 | 74.3 | 72.3 | 20.0 | |
4 | 3.8 | 65.3 | 63.3 | 23.0 | |
16 | 7.6 | 56.2 | 54.2 | 25.0 | |
25 | 9.5 | 53.3 | 51.3 | 24.3 | |
62.5 | 15.4 | 47.7 | 45.7 | 21.5 | |
100 | 19.8 | 44.3 | 42.3 | 20.1 | |
200 | 29.0 | 39.8 | 37.8 | 18.0 | |
250 | 32.8 | 38.3 | 36.3 | 17.3 |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
66048RTVBK-5H | Draka UCDATA CATEGORY CABLE UC400 CAT.6 UFTP 4 PAIR 23AWG LSFRZH ATARUV BLACK IEC60332-3-24, IEC60754-1&2, IEC 61034 | 500m/drum |
Draka UC500 Cat.6a S/FTP SWB LSZH AR_AT_UV
Category cable for demanding environments
Construction | |
---|---|
Conductor | Solid copper wire (AWG23) |
Insulation | Foam PE |
Twisting | 2 cores to the pair |
Pair Screen | High Performance Individual Pair Screen |
Overall screen | Tinned Copper Braid |
Inner Sheath | LSZH |
Armouring | Galvanized Steel Wire Braid |
Outer sheath | LSZH (AR-AT-UV) |
Sheath colour | Black |
Mechanical properties | ||
---|---|---|
Bending radius | Installation (No Load) | 8 x D |
Temperature range | During operation | -20°C to + 70°C |
During installation | 0°C to + 50°C |
Electrical properties at 20°C | ||
---|---|---|
DC Loop resistance | – | ≤ 187.6Ω/km |
DC Resistance Unbalance | – | ≤ 4% |
Characteristic impedance | 1-100Mhz | 100 ± 15 Ω |
Mutual capacitance | at 1kHz | ≤ 5.6nF/100m |
Capacitance unbalance | (pair to ground) | ≤ 300 pF/100m |
Nom. Velocity of Propagation | – | 76% |
Application
- Generic Data transmission. This cable is a Cat6a S/FTP cable is meant for use as installation/horizontal cable in demanding electrical and mechanical environment.
- Suitable for installation in Anti-Termite, Anti-Rodent & UV Resistance area.
Standards
- ANSI/TIA 568.2-D;
- ISO/IEC 11801-1/2 ; IEC 61156 – 5
- EN 50173; EN 50288- 5 -1
Flame Rating
- IEC 60332 – 1
Electrical Data Nominal at 20°C | ||||
---|---|---|---|---|
Freq. | Max. Attenuation | Min. Return loss | Min. NEXT | |
(MHZ) | (dB) | (dB) | (dB) | |
1 | 2.1 | 20 | 74.3 | |
4 | 3.8 | 23 | 65.3 | |
16 | 7.5 | 25 | 56.2 | |
100 | 19.1 | 20.1 | 44.3 | |
250 | 31.1 | 17.3 | 38.3 | |
500 | 45.3 | 15.2 | 33.8 | |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
85075BRTVBK-5H | Draka UCDATA CATEGORY CABLE UC500 CAT.6A SFTP 4 PAIR 23AWG GSWB Armoring LSZH ATARUV Black IEC60332-1, IEC 60754-1&2, IEC 61034 | 500m/drum |