Category: product
Category 7
FIRETUF LTFIPNWM Fire Resistance SERIES
Heavy Armoured Cable Nylon + LSZH Sheath, Chemical/Corrosive Resistant
Features
- Central Strength Member(CSM): glass fiber reinforced plastic rod(FRP), with PE coating when needed.
- Tube: thermoplastic material containing up to 12 optical fibres and filled with a suitable water tightness compound.
- Fire Resistance Layer: mica tape wrapped around loose tube
- Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
- Core Wrapping: water-blocking tape & yarn (dry-core)
- Inner sheath: HDPE
- Nylon sheath: Black Nylon Polyamide 12 (PA 12)
- Outer Armour: Galvanized Steel Wire
- Outer Sheath: LSZH flame retardant
Technical Data | ||||||
---|---|---|---|---|---|---|
No.of Flbres | 4,8,16 | 12,24,36,48,72 | 96 | |||
Design (Elements x Fibre/Tube) | 6×4 | 6 x 12 | 8×12 | |||
Loose Tube/Filler – ø | mm | Nom. 2.3 | Nom. 2.0 | Nom. 2.0 | ||
CSM/sheath diameter | mm | Nom. 3.0 | Nom. 3.0 | Nom. 3.0/4.8 | ||
Outer sheath thickness | mm | Nom. 2.0 | ||||
Cable Diameter | mm | Nom. 17.9 | Nom. 17.9 | Nom. 19.7 | ||
Cable Weight | Kg.Km | 531 | 531 | 624 | ||
Max installation tension | N | 6000 | ||||
Min. bending radius | mm | Without Tension 15 x Cable- ø |
Under Maximum Tension 30 x Cable- ø |
|||
Temperature range | Installation : -10°C->+60°C |
Transport & Storage : -40°C->+70°C |
Transport & Storage: -40°C->+70°C |
Application
The cable is specially designed for harsh environments. The multilayer inner sheath HDPE/PA(nylon) withstands aggressive constituents, fluids that might occur on (petro) chemical plants, aliphatic hydrocarbon resistant. The cable which is low smoke, halogen free and flame-retardant, is suitable for installation under and above ground. – Nylon jacket provides anti-termite protection of the cable
– The steel wire armour provides anti-rodent protection
– The outer sheath is flame retardant compound to Heat & Oil and UV resistant
Flame & Fire Rating
- IEC 60332-3-24 & IEC 60331-25
Main Characteristics | |||
---|---|---|---|
Test | Standard | Specified value | Acceptance Criteria* |
Max. tension at installation (short term) | IEC 60794-1-2-E1 | 5000N | Δ I/I fibre strain ≤ 0.6%, Δα reversible |
Crush | IEC 60794-1-2-E3 | 4000N/100mm | Δα ≤ 0.15dB(SM), 0.3 dB (MM) after test |
Temperature Range | IEC 60794-1-2-F1 | -40 -> + 70ºC | Δα ≤ 0.15dB/km(SM), 0.3 dB /km(MM) |
Water penetration | IEC 60794-1-2-F5C | sample=3m, water=1m | No water leakage after 24 hour |
* Values for single-mode fibres, all optical measurements performed at 1550 nm
* Values for multi-mode fibres, all optical measurements performed at 1300 nm
Ordering Information | ||
---|---|---|
FIRETUF LTFIPNWM SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters LTFIPNWM to denote that it is a FIRETUF LTFIPNWM SERIES FO Cable. This is followed by 3 numbers which symbolizes the core quantity and then 2 letters to denote the fibre type. Example of a FIRETUF LTFIPNWM SERIES FO Cable part number: LTFIPNWM008M1 The above example describes an OM1 (62.5um, Black Sheath) FIRETUF LTFIPNWM SERIES FO Cable, with 8 cores. |
LTFIPNWM SERIES |
Core quantity |
FIBER TYPE |
LTFIPNWM |
XXX |
XX |
---|---|---|
002~096 : (2 CORES ~ 96 CORES) |
SM - SingleMode M1~M4 - MultiMode |
Category 3 UTP Multipair
U/UTP Data Cable

Application
These cables are used as riser cable in structured cabling networks, most often between distribution frames
Standards
- IEC 61156, ISO/IEC 11801/1995, TIA/EIA 568 – A
Flame Rating
- PVC IEC 60332 – 1,
- LSZH IEC 60332-1
Construction | ||||||
---|---|---|---|---|---|---|
Conductor | Solid bare copper wire, diameter 0.5 mm | |||||
Insulation | Polyethylene, PE | |||||
Sheath | PVC Black , also available on request with LSZH |
Mechanical Properties | ||
---|---|---|
Minimum bending radius | Without load | 4 x OD ( OD= outer diameter ) |
With load | 8 x OD ( OD= outer diameter ) | |
Temperature | During operation | – 20° C to + 70° C |
During operation | 0° C to + 50° C |
Electrical Properties | |
---|---|
DC Resistance | ≤ 117 Ω/ km |
Insulation DC Resistance | ≤ 5000 M Ω . km |
Electrical Data at 20°C | |||||
---|---|---|---|---|---|
Frequency | Max.Attenuation | Min. NEXT | Min. ELFEXT | Min. Return Loss | |
(MHZ) | (dB) | (dB) | (dB) | (dB) | |
4 | 5.6 | 32.3 | 27.0 | 12.0 | |
8 | 8.5 | 27.8 | 20.9 | 12.0 | |
10 | 9.7 | 26.3 | 19.0 | 12.0 | |
16 | 13.1 | 23.2 | 14.9 | 10.0 |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
ISV30250GY-5H | Draka MMS Special Category 3 U/UTP 2 X 0.5mm PVC | 500m/drum | |
ISV31050GY-5H | Draka MMS Special Category 3 U/UTP 10 X 0.5mm PVC | 500m/drum | |
ISV32050GY-5H | Draka MMS Special Category 3 U/UTP 20 X 0.5mm PVC | 500m/drum | |
ISV32550GY-5H | Draka MMS Special Category 3 U/UTP 25 X 0.5mm PVC | 500m/drum | |
ISV310050GY-5H | Draka MMS Special Category 3 U/UTP 100 X 0.5mm PVC | 500m/drum | |
LTFPNWM Flame Retardant SERIES
Heavy Armoured Cable Nylon + LSZH Sheath, Chemical/Corrosive Resistant
Application
- The cable is specially designed for harsh environments. The multilayer inner sheath HDPE/PA(nylon) withstands aggressive constituents, fluids that might occur on (petro) chemical plants, aliphatic hydrocarbon resistant. The cable which is low smoke, halogen free and flame-retardant, is suitable for installation under and above ground. – Nylon jacket provides anti-termite protection of the cable
– The steel wire armour provides anti-rodent protection
– The outer sheath is flame retardant compound to Heat & Oil and UV resistant
Flame Rating
- IEC 60332-3-22
Features
- Central Strength Member(CSM): glass fiber reinforced plastic rod(FRP)
- Tube: thermoplastic material containing up to 12 optical fibres and filled with a suitable water tightness compound.
- Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
- Core Wrapping: water-blocking tape & yarn (dry-core)
- Inner sheath: HDPE
- Nylon sheath: Black Nylon Polyamide 12 (PA 12)
- Outer Armour: Galvanized Steel Wire
- Outer Sheath: LSZH flame retardant
Configuration | ||||
---|---|---|---|---|
No. of Flbers | 4,8,12,24 | 32 | 36,48,72 | |
Design (Elements x Fibre/Tube) | 6×4 | 6×8 | 6×12 | |
Loose Tube/Filler – ø | mm | Nom. 2.1 | Nom.2.1 | Nom. 2.1 |
CSM/sheath diameter | mm | Nom. 2.3 | Nom. 2.3 | Nom. 2.3 |
Outer sheath thickness | mm | Nom. 2.0 | ||
Cable Diameter | mm | Nom. 16.4 | Nom.16.4 | Nom. 16.4 |
Cable Weight | kg.km | 436 | 436 | 436 |
Max installation tension | N | 5000 | ||
Min. bending radius ( Without Tension) | mm | 15 x Cable ø | ||
Min. bending radius ( Under Max. Tension) | 25 x Cable ø |
Main Mechanical and Environmental characteristics | ||||
---|---|---|---|---|
Test | Standard | Specified value | Acceptance Criteria* | |
Max. Tension | IEC 60794-1-2-E1 | See Configuration |
Δ I/I fibre strain ≤ 0.6%, |
|
Crush | IEC 60794 1-2-E3 | 4000 N/100 mm; reversible |
Δα ≤ 0.15dB(SM), 0.3 dB (MM) |
|
Water penetration | IEC 60794 1-2-F5C | Sample=3m,water column=1m |
No water leakages after 24hours |
|
Temperature Range | Transportation & Storage | -40° C to +70 ° C | ||
Installation | -10° C to + 70° C | |||
Operation | -40° C to +70 ° C |
* Values for single-mode fibres, all optical measurements performed at 1550 nm
* Values for multi-mode fibres, all optical measurements performed at 1300 nm
Ordering Information |
---|
LTFPNWM SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters LTFPNWM to denote that it is a LTFPNWM SERIES FO Cable. Cable part number: LTFPNWM008M1 |
LTFIPNWM SERIES | Core Qty | FIBRE TYPE | |
LTFPNWM | XXX |
XX |
|
---|---|---|---|
012-12 CORES
016-16 CORES 024-24 CORES 048-48 CORES 096-96 CORES
|
SM-SINGLEMODE, G652D, 9µm |
Draka Fire Resistant UC500 Cat.6a SFTP GSWB LSFRZH
Cat.6a 23AWG GSWB SFTP LSZH with circuit integrity behaviour

Application
- Primary(Campus), Secondary(Riser), Tertiary(Horizontal)
- IEEE 802.3: 10G Base-T
- IEEE 802.5 16 MB; ISDN; TP DDI;ATM
Standards
- ANSI/TIA-568.2-D
- ISO/IEC 11801-1/2
- IEC61156-5
Flame & Fire Rating
- IEC 60331-23, IEC60332-1, IEC60332-3-24
Construction | |
---|---|
Conductor | Solid copper wire, (AWG 23) |
Insulation | Foam PE with special fire barrier tape |
Twisting | 2 cores to the pair |
Screen | Individual Pair Screen + Tinned Copper Braid Screen |
Sheath | LSZH with ATARUV |
Tensile force | 100 N |
Mechanical Properties | ||
---|---|---|
Bending radius | without load | ≥ 16 x OD |
with load | ≥ 8 x OD | |
Temperature range | during operation | -15°C to + 60°C |
during installation | 0°C to + 50°C |
Electrical Properties | ||
---|---|---|
DC Loop resistance | – | ≤ 187.6 Ω/km |
Impedance | 1-100MHz | Nom. 100 Ω |
DC Resistance unbalance | – | ≤ 4% |
Mutual capacitance | at 1kHz | ≤ 5.6 nF/100m |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
85048FRBRTVBK-3H | Draka UCDATA Category Cable UC500 CAT.6A SFTP 4 PAIR 23AWG GSWB LSFRZH FR ATARUV | 305m/drum |
MAX-FOH Flexible PAGA & Control Cable
Public Address General Alarm, Data Control Cable, Fire Resistance
Fire Characteristics | |
---|---|
Conductor | Grade A Copper specially protected by fire barrier tape to ensure circuit integrity in fire situations. |
Construction | Twisted pair for better signal transmission. |
Core Insulation | Cross-linked PE, XLPE |
Outer Sheath | LSZH in accordance to IEC 61034, IEC 60754-1 & 2. |
Main Characteristics | ||
---|---|---|
Nominal overall diameter | mm | As per Technical Datasheet |
Nominal weight (completed cable) | Kg/km | As per Technical Datasheet |
Min bending radius | mm | As per Technical Datasheet |
Max pulling tension | kgf | As per Technical Datasheet |
Max conductor resistance @ 20°C | Ω/km | As per Technical Datasheet |
Min insulation resistance @ 20°C | MΩ/km | As per Technical Datasheet |
Dielectric withstand test | kV/min | As per Technical Datasheet |
Technical Details | ||
---|---|---|
Size | – | As per Technical Datasheet |
Specification reference | – | IEC 60332-1, IEC60332-3A, IEC 60331, BS 6387 CWZ |
Conductor material | mm | Plain annealed copper wire to IEC |
Max operating temperature | °C | 90 |
No of Wire / Wire Diameter | mm | As per Technical Datasheet |
Conductor shape | – | Circular stranded |
Insulation | – | Cross-linked PE, XLPE |
Insulation thickness | mm | As per Technical Datasheet |
Core Colour | mm | Black & White |
Application
- Most widely used fire resistance speaker & Audio/Motor control cables, which is highly flexible due to the unique tubing design. Draka MAX – FOH flexible speaker cables meets the stringent BS 6387 fire performance standards and can be used in all critical Public Address General Alarm Systems.
Fire Rating
- Generally to :ISO/IEC 11801:95, IEC 61156, EN 50173:95; EN 50288-1,BS 6387
Ordering Information | ||
---|---|---|
P/N | Product Description | P.U |
PAGA2C15 | MAX-FOH FlexiTube, 2Cx1.5mm², PAGA Fire Res,
BS 6387, IEC 60331, LSZH, Orange |
500m/drum |
PAGA3C15 | MAX-FOH FlexiTube, 3Cx1.5mm², PAGA Fire Res,
BS 6387, IEC 60331, LSZH, Orange |
500m/drum |
PAGA2C25 | MAX-FOH FlexiTube, 2Cx2.5mm², PAGA Fire Res,
BS 6387, IEC 60331, LSZH, Orange |
500m/drum |
PAGA3C25 | MAX-FOH FlexiTube, 3Cx2.5mm², PAGA Fire Res,
BS 6387, IEC 60331, LSZH, Orange |
500m/drum |
Draka Style 2919
Individual Pair Screened Control Cable

Application
- For installation require flexible cable to fulfill measuring, controls & command applications. Example Computer Interconnection, Data Transmission, Control Circuits, Industrial Equipment Control, suitable for RS-485 applications.
Optional
- PVC/Steel Wire Braid
- High pair counts upon request.
Technical Details | |
---|---|
Conductor | Stranded Tinned Copper |
Operating Voltage | 300V |
Insulation | HD-PE/Foam-PE |
Insulation colour | Pair 1: White*Orange |
1st screen | 1 x AL-Mylar Wrap, overlapping >= 25 % |
Drain wire | 7/0.254mm Stranded Tinned Copper |
Braid Shielding | Tinned Copper Braid |
Sheath | LSZH |
Sheath Colour | Grey |
Operating Temperature | -20°C ~ +70°C |
Cable Dimension | |||
---|---|---|---|
Conductor Size | DC Resistance @ 20°C (Ω/km) | No of Pairs | Nom. OD (mm) |
18 AWG | <= 23.2 | 1 Pair | 7.5 |
<= 23.2 | 2 Pairs | 10.3 | |
<= 23.2 | 4 Pairs | 12.8 | |
20 AWG | <= 36.7 | 1 Pair | 7.0 |
<= 36.7 | 2 Pairs | 9.3 | |
<= 36.7 | 4 Pairs | 11.5 | |
22 AWG | <= 58.0 | 1 Pair | 6.5 |
<= 58.0 | 2 Pairs | 9.8 | |
<= 58.0 | 4 Pairs | 11.5 | |
24 AWG | <= 89.0 | 1 Pair | 6.5 |
<= 89.0 | 2 Pairs | 9.0 | |
<= 89.0 | 4 Pairs | 10.2 |
Ordering Information |
---|
Draka Style 2919 part numbers are made up using the table below. The part number starts with 29 to denote that it is a UL 2919 cable. The following number shows the number of pairing and the last 2 numbers signifies the AWG. Any letter behind would describe the sheath & colour type. Example of a Draka Style 2919 part number : 29418LGY The above example describes an UL 2919 cable with 4 pairing, 18 AWG. Sheath type LSZH. |
UL 2919 | PAIRING | AWG | SHEATH | Colour | |
29 | X | XX | X | X | |
---|---|---|---|---|---|
1 - 1 Pair 2 - 2 Pair 3 - 3 Pair 4 - 4 Pair |
18 - 18 AWG 20 - 20 AWG 22 - 22 AWG 24 - 24 AWG |
(nil) - PVC L- LSZH |
GY - GREY BK- BLACK |
Draka Style 2464
Technical Details | |
---|---|
Conductor | Stranded Tinned Copper |
Operating Voltage | 300V |
Insulation | SR-PVC |
Insulation colour | White/Brown, Green/Yellow, Gray/Pink, Blue/Red |
Drain wire(Construction,mm) | 7/0.254mm Stranded Tinned Copper |
Screen | Overall Foil Shield + Drain Wire |
Sheath | PVC/LSZH |
Operating Temperature | -20°C to +70°C |
Cable Dimension | |||
---|---|---|---|
Conductor Size | DC Resistance @ 20°C (Ω/km) |
No of Pairs | Nom. OD (mm) |
16 AWG | ≤ 14.5 | 1 Pair | 6.2 |
≤ 14.5 | 2 Pair | 9.0 | |
≤ 14.5 | 4 Pair | 11.0 | |
18 AWG | ≤ 23.2 | 1 Pair | 5.6 |
≤ 23.2 | 2 Pair | 8.0 | |
≤ 23.2 | 4 Pair | 10.0 | |
20 AWG | ≤ 36.7 | 1 Pair | 5.0 |
≤ 36.7 | 2 Pair | 6.4 | |
≤ 36.7 | 4 Pair | 7.7 | |
22 AWG | ≤ 59.4 | 1 Pair | 4.6 |
≤ 59.4 | 2 Pair | 5.5 | |
24 AWG | ≤ 94.2 | 1 Pair | 4.0 |
≤ 94.2 | 2 Pair | 5.0 | |
≤ 94.2 | 3 Pair | 5.8 | |
≤ 94.2 | 4 Pair | 6.7 |
Application
- For installation requiring flexible connector cable to fulfill measuring,controls & command applications. Example : Computer Interconnection,Data Transmission,Control Circuits,Industrial Equipment Control,suitable for EIA RS-232 applications.
Ordering Information | |||
---|---|---|---|
Draka Style 2464 part numbers are made up using the table below. The part number starts with 24 to denote that it is an UL 2464 cable. The following number shows the number of pairing and the last 2 numbers signifies the AWG. The following letter describes the sheath type & colour. Example of an UL 2464 part number - 24116GY The above example describes an UL 2464 cable with 1 pair, 16 AWG. Sheath type PVC. |
UL 2464 | PAIRING | AWG | SHEATH | Colour | |
24 | X | XX | X | X | |
---|---|---|---|---|---|
1 - 1 Pair 2 - 2 Pair 3 - 3 Pair 4 - 4 Pair |
16 - 16 AWG 18 - 18 AWG 20 - 20 AWG 22 - 22 AWG |
(nil) - PVC L- LSZH |
GY-Grey |
Draka RS-485 24 AWG FPE
Serial Data Communication Cable
Construction | |
---|---|
Conductor | Stranded Tinned Copper |
Insulation | Foam PE |
Colour | Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange Pair 3: 1 x white, 1 x black Pair 4: 1 x green |
1st Screen | 1 x AL-Mylar Wrap, overlapping ≥ 25 % |
Drain Wire | Stranded Tinned Copper |
Braid Shield | Tinned Copper ; coverage ≥ 85% |
Sheath | PVC/LSZH/LSZH ATARUV |
Braid Armour (Optional) | Galvanized Steel Wire Braid |
Outer Sheath (Optional) | LSZH / LSZH ATARUV |
Pair | 1P | 2P | 3P | 4P |
Nom. Cable OD mm | ||||
TC/FPE/OS/TCWB/PVC | 6.2 | 8.5 | 9.1 | 9.8 |
TC/FPE/OS/TCWB/LSZH | 6.2 | 8.5 | 9.1 | 9.8 |
TC/FPE/OS/TCWB/LSZH ATARUV | 6.2 | 8.5 | 9.1 | 9.8 |
TC/FPE/OS/TCWB/LSZH/SWB/LSZH | 10.7 | 13.0 | 13.6 | 14.3 |
Application
- For multi-dropped,medium-speed,serial data communication in electrically noisy industrial environments.Application includes industrial networks using RS-485/RS- 422/RS-232 transceivers, for Process Automation (chemicals, brewing, paper mills), factory automation (autos, metal fabrication), HVAC, security, motor control and motion control.Suitable for outdoor installation.
Flame Rating
- IEC 60332 – 1
Electrical properties | |||||||||
---|---|---|---|---|---|---|---|---|---|
Conductor Resistance (at 20ºC) | ≤ 89 Ω/km | ||||||||
Capacitance cond. to cond. | Nom. 12.5 pF/ft | ||||||||
Impedance | Nom. 120 Ω | ||||||||
Rated Voltage | 300 V |
Mechanical properties | |||||||||
---|---|---|---|---|---|---|---|---|---|
Operating temperature | -20°C to +70°C | ||||||||
Bend Radius | 10 x OD | ||||||||
Ordering Information | |||
---|---|---|---|
RS-485 part numbers are made up using the table below. The part number starts with 48 to denote that it is an EIA-485 cable. The following number shows the number of pairing and the last 2 numbers signifies the AWG. Example of an EIA-485 part number 48124LB The above example describes an RS-485 SWB cable with 1 pair, 24 AWG. Sheath type LSZH, SWB |
RS- 485 | PAIRING | AWG | SHEATH | OUTER JACKET | ADDITIVE | |
48 | X | XX | X | X | X | |
---|---|---|---|---|---|---|
1 - 1 Pair 2 - 2 Pair 4 - 4 Pair |
24 -24 AWG |
(nil) - PVC L- LSZH |
B - SWB |
RTV- Anti-Rodent, Anti-Termite, UV Resistance |