Construction | |||
---|---|---|---|
Material | Detail | mm | |
Inner Conductor | Bare Copper ( BC ) | 0.81 | |
Dielectric | Foam PE | 3.66 | |
First Shield | Aluminum/Polymer/Aluminum (APA) Bonded | N.A | |
Second Shield | 36 AWG Aluminum Braid (ALB) 95% coverage | N.A | |
Third shield | Aluminum/Polymer/Aluminum (APA) Bonded | N.A | |
Forth Shied | 36 AWG Tinned Copper Braid 95% coverage | N.A | |
Outer Jacket | PVC CMR/ LSZH / PE | 6.60 | |
Fire Performance | IEC 60332-1 | N.A | |
Bending Radius | 10 x O.D. |
Electrical Characteristics | |||
---|---|---|---|
Impedance, Ω | 75 ± 3.0 Ohm/td> | ||
Capacitance, Nominal | 52 ± 3 pF/m | ||
Velocity of Propagation, % | > 83% | ||
Return Loss | 5 - 1000 MHz ≥ 20dB 1000 - 3000 MHz ≥ 20dB |
Ordering Information | |||
---|---|---|---|
P/N | Product Description | P.U | |
RG917A | RG59, BC, 95% Aluminum Braid, APA, 95% Aluminum Braid, PVC CMR, 75 Ohm | 500m/reel | |
RG927A | RG59, BC, 95% Aluminum Braid, APA, 95% Aluminum Braid, LSZH, 75 Ohm | 500m/reel | |
RG967A | RG59, BC, 95% Aluminum Braid, APA, 95% Aluminum Braid, PE, 75 Ohm | 500m/reel |