Li-2YC11Y 2 x 2 x 0.22 mm² FRNC

CanBus-Cable

Application

  • The following CanBus cable is suitable for transmission of CanBus signals according to DIN19245 and EN 50170
  • The following CanBus cable is suitable for transmission of CanBus signals according to ISO 11898 - 2
  • The cable is suited for fixed indoor and outdoor installation and under certain conditions also for mobile use.
  • The cable is halogen free,flame retardant and oil resistant. The sheath material is tested in Hydraulic oil.
  • ARAL VITAM 32, Mobil DTE 13 M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320

Standards

acc. To customer Specification

Flame resistance

  • IEC 60332 - 1,IEC -60332-3,IEC 60754 - 1 /2
Construction
Conductor stranded bare copper wire, diameter 7 x 0.20 mm Φ 0.60 mm(cross section 0.22 mm²)
Insulation PE, Φ1.75 ± 0.05 mm Wall Thickness 0.46mm
Colour code Pair 1: 1 x white, 1 x brown
Core identification Pair 2: 1 x yellow, 1 x green
Cable lay up 4 cores twisted to a star quad Φ 4.2 mm
Wrapping 1 x PET-foil, overlapping Φ 4.3 mm
Overall screen Tinned copper braid Φ 5.0 mmOptical coverage ≥ 85%
Foil 1 x PET-foil under sheath Φ 5.1 mm
Sheath PUR Low Smoke Zero Halogen Φ 6.9 ± 0.2 mm
Sheath colour Black, RAL 9005
Outer Diameter Nom. 6.9 mm
Weight Nom. 70 kg/km
Tensile force N 165
Mechanical properties
Bending radius - moving application- fixed application   ≥ 10 x outer diameter of cable≥ 5 x outer diameter of cable
Operating temperature - 40°C up to + 85°C
UV resistance acc. to IEC60068-2-5
Testing of oil resistance of PU sheath material acc.to VDE 0282 Part 10 and EN 60811-2-1 and thermal endurance graph (Arrhenius) and life expectancy of PU sheath material acc. to ISO 2578 Requirements after aging: max. change of tensile strength: -50% max. change of elongation at break: -50% Mobil DTE 13 M (Hydraulic oil)%   Tribol 1710/20 (Gear oil) 150 days at 100°C approx. 24 years at 65°C ≥ 25 years at 20°C 140 days at 100°C approx. 18 years at 65°C ≥ 25 years at 20°C
Ozone resistance acc. to EN 60811-2-1, clause 8
Smoke density acc. to EN 50268-2, IEC61034-1 and 2
Corrosivity EN 50267-1 and 2, IEC 60754-1 and 2
Electrical properties at 20°C
Conductor resistance (at 20 ± 5 °C) ≤ 87 Ω/km
Characteristic impedance at 1 MHz 120 Ω ± 15%
Capacitance at 800 Hz (nominal) 41 nF/kmm
Insulation resistance (at 20 ± 5 °C and 500 V) ≥ 10 GΩxkm
Capacitance unbalance (pair to ground) 1.2 kV
Ordering Information
P/N Product Description P.U
1003018 CS2878600 CanBus, Li-2YC11Y 2 x 2 x 0.22 mm² FRNC 1000m/drum