Security & Comms Cable, SXACS Series

Shielded, LSZH

 

 

Application

  • Security, Intercom, Broadcast, Sound, Audio Systems

Flame rating

  • LSZH IEC 60332-1
Construction
Conductor
Grade A Bare Copper, Stranded
Operating Voltage
300V
Insulation
XLPE
Insulation colour
1 - Black, 2 - Red, 3 - White, 4 - Green
1st Screen
100% Overall Aluminum Foil Screen
Sheath
LSZH with Ripcord
Sheath colour
Grey , Red
Rated temperature
Up to 75°C
Cable Dimension
Conductor Size No of Pairs OD (mm)
12 AWG 1 Pair 7.6
  2 Pairs 11.3
14 AWG 1 Pair 6.6
  2 Pairs 9.7
16 AWG 1 Pair 5.2
  2 Pairs 7.6
18 AWG 1 Pair 4.6
  2 Pairs 6.6
20 AWG 1 Pair 4.2
  2 Pairs 6.1
22 AWG 1 Pair 3.8
  2 Pairs 5.3
 
Ordering Information
SXACS Series part numbers are made up using the table below.
The part number starts with SXACS to denote that it is a SXACS cable.
The following number shows the number of pairs and the last 2 numbers signifies the AWG.
Any letter behind would describe the sheath type and colour.

Example of a SXACS part number-SXACS1P22LRD-3H
The above example describes SXACS cable with 1 pairing, 22 AWG. Sheath type LSZH.

 

SXACS PAIRING AWG SHEATH Colour Drum Length
SXACS X XX X X – X
  1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
20 – 20 AWG
22 – 22 AWG

L- LSZH

GY-Grey
RD- Red

 

-3H : 305m

-5H : 500m

 

Fire Alarm Cable, FACS Series

Shielded, PVC CMR, PE, LSZH

Application

  • Widely used in indoor fire alarm, security alarm & Intercom system requiring flame retardancy properties.

Flame rating

  • NEC Article Type FPLR,CL3R, PVC CMR Rated comply to IEC 60332-1
  • LSZH IEC 60332-1
Construction
Conductor Grade A Bare Copper, Solid
Operating Voltage 300V
Insulation PVC
Insulation colour 1 – Black, 2 – Red, 3 – White, 4 – Green
1st Screen 100% Overall Aluminum Foil Screen
Sheath PVC-CMR or LSZH with Ripcord
Sheath colour PVC-CMR or LSZH RED
Rated temperature Up to 75°C
Cable Dimension
Conductor Size No of Pairs Nom. OD (mm)
12 AWG 1 Pair 6.5
2 Pairs 10.3
14 AWG 1 Pair 5.6
2 Pairs 8.9
16 AWG 1 Pair 4.8
2 Pairs 7.5
18 AWG 1 Pair 4.3
2 Pairs 6.7
Ordering Information
FACS 12-18 AWG part numbers are made up using the table below.
The part number starts with FACS to denote that it is a FACS cable.
Following number shows the number of pairing and the last 2 numbers signifies the AWG. 
Any letter behind would describe the sheath type & colour.

Example of a FACS part number-FACS1P18LRD
The above example describes an FACS cable with 1 pairing, 18 AWG. Sheath type LSZH with Red Jacket.

FACS PAIRING AWG SHEATH  Colour
FACS X XX X
1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
C – PVC-CMR
L- LSZH
RD- Red

Fire Alarm Cable, FACU Series

Unshielded, PVC CMR, PE, LSZH

Application

  • Widely used in indoor fire alarm or intercom system requiring flame retardancy properties.

Flame rating

  • NEC Article Type FPLR, CL3R, PVC CMR comply to IEC 60332-1
  • LSZH IEC 60332-1
Construction
Conductor Grade A Bare Copper, Solid
Operating Voltage 300V
Insulation PVC
Insulation colour 1 – Black, 2 – Red, 3 – White, 4 – Green
Ripcord Available
Sheath colour PVC-CMR or LSZH (Colour : RED)
Rated temperature Up to 75°C
Cable Dimension
Conductor Size No of Pairs OD (mm)
12 AWG 1 Pair 6.5
2 Pairs 10.3
14 AWG 1 Pair 5.6
2 Pairs 8.9
16 AWG 1 Pair 4.8
2 Pairs 7.5
18 AWG 1 Pair 4.3
2 Pairs 6.7
Ordering Information
FACU 12-18 AWG part numbers are made up using the table below.
The part number starts with FACU to denote that it is a FACU cable. 
The following number shows the number of pairs and the last 2 numbers signifies AWG. 
Any letter behind would describe the sheath type and sheath colour.

Example of a FACU part number-FACU2P12LRD
The above example describes an FACU cable with 2 pairing, 12 AWG. Sheath type PVC-CMR.

FACU PAIRING AWG SHEATH Colour
FACU X XX X X
1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
C – PVC-CMR
L- LSZH
RD-Red

Security & Comms Cable, SACS Series

Shielded, PVC CMR, PE, LSZH

Application

  • Security, Intercom, Broadcast, Sound, Audio Systems

Flame rating

  • PVC NEC Article Type FPLR, CL3R, CMR, comply to IEC 60332-1
  • LSZH IEC 60332-1
Construction
Conductor Grade A Bare Copper, Stranded
Operating Voltage 300V
Insulation PVC
Insulation colour 1 – Black, 2 – Red, 3 – White, 4 – Green
1st Screen 100% Overall Aluminum Foil Screen
Sheath PVC-CMR, PE or LSZH with Ripcord
Sheath colour PVC-CMR or LSZH Grey; PE Black
Rated temperature Up to 75°C
Cable Dimension
Conductor Size No of Pairs OD (mm)
12 AWG 1 Pair 7.6
2 Pairs 11.3
14 AWG 1 Pair 6.6
2 Pairs 9.7
16 AWG 1 Pair 5.2
2 Pairs 7.6
18 AWG 1 Pair 4.6
2 Pairs 6.6
20 AWG 1 Pair 4.2
2 Pairs 6.1
22 AWG 1 Pair 3.8
2 Pairs 5.3
Ordering Information
SACS Series part numbers are made up using the table below.
The part number starts with SACS to denote that it is a SACS cable.
The following number shows the number of pairs and the last 2 numbers signifies the AWG.
Any letter behind would describe the sheath type and colour.

Example of a SACS part number-SACS1P22LGY
The above example describes SACS cable with 1 pairing, 22 AWG. Sheath type LSZH.

SACS PAIRING AWG SHEATH Colour Drum Length
SACS X XX X X – X
1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
20 – 20 AWG
22 – 22 AWG
(nil) – PVC-CMR
E – PE
L- LSZH
GY-Grey -3H : 305m

Security & Comms Cable, SACU Series

Unshielded, PVC CMR, PE, LSZH

Application

  • Security, Intercom, Broadcast, Sound, Audio Systems

Flame rating

  • PVC NEC Article Type FPLR, CL3R, CMR, comply to IEC 60332-1
  • LSZH IEC 60332-1
Construction
Conductor Grade A Bare Copper, Stranded
Operating Voltage 300V
Insulation PVC
Insulation colour 1 – Black, 2 – Red, 3 – White, 4 – Green
Ripcord Available
Sheath colour PVC-CMR or LSZH Grey; PE Black
Rated temperature Up to 75°C
Cable Dimension
Conductor Size No of Pairs OD (mm)
12 AWG 1 Pair 7.5
2 Pairs 11.2
14 AWG 1 Pair 6.5
2 Pairs 9.6
16 AWG 1 Pair 5.1
2 Pairs 7.5
18 AWG 1 Pair 4.5
2 Pairs 6.5
20 AWG 1 Pair 4.1
2 Pairs 6.0
22 AWG 1 Pair 3.7
2 Pairs 5.2
Ordering Information
SACU Series part numbers are made up using the table below.

The part number starts with SACU to denote that it is a SACU cable.
The following number shows the number of pairs and the last 2 numbers signifies the AWG.
Any letter behind would describe the sheath type and jacket colour.

Example of a SACU part number-SACU1P16CGY 

The above example describes SACU cable with 2 pairs, 16 AWG. Sheath type PVC CMR with Grey jacket

SACU PAIRING AWG SHEATH  Colour
SACU X XX X X
1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
20 – 20 AWG
22 – 22 AWG
(nil) – PVC-CMR
E – PE
L- LSZH
GY-Grey